首页 SOLIDEX® SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect)

SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect)

🏷 GM-Tg-hg-T56365-dep-kit
Indirect柱式Non-releasable
SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,间接法)是一种间接B细胞去除试剂盒(柱式,不可释放)

订购信息

产品货号 产品名称 规格 价格 (USD)
GM-Tg-hg-T56365-dep-kit-10T SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect) 10 Tests $112
GM-Tg-hg-T56365-dep-kit-50T SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect) 50 Tests $336
GM-Tg-hg-T56365-dep-kit-100T SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect) 100 Tests $591
GM-Tg-hg-T56365-dep-kit-750T SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect) 750 Tests
SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect)

产品规格

  • 目标细胞群 B细胞
  • 标记类型 Indirect
  • 磁珠类型 Non-releasable
  • 分选方式 柱式
  • 分离方法 B 细胞去除
  • 储存条件 2℃ - 8℃ 保存

产品详情

产品货号 GM-Tg-hg-T56365-dep-kit
产品名称 SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect)
英文名称 SOLIDEX®-ISOEx Indirect Human CD19+ B Cell Depletion Kit (Column-based)
产品详情 SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,间接法)是一种间接B细胞去除试剂盒(柱式,不可释放)
应用详情 SOLIDEX®-ISOEx 人CD19+B细胞去除试剂盒(柱式,Indirect)用于B细胞去除,其主要特点包括:特异性细胞去除;非特异性结合少;适用于复杂样本
组分
  • GM-Tg-hg-T56365-Ab-1-Biotin-50μL/250μL/500μL/3.75mL: SOLIDEX®-ISOEx Anti- 人CD19+ B细胞 monoclonal antibody(mAb) (Biotin)-50μL/250μL/500μL/3.75mL
  • GMP-SMT-219-Ab01-nanoIMB-100μL/0.5mL/1mL/7.5mL: SOLIDEX®-ISOEx 抗生物素纳米磁珠 (柱式)-100μL/0.5mL/1mL/7.5mL
标记类型 Indirect
磁珠类型 Non-releasable
分选方式 柱式
关键特性 特异性细胞去除;极低的非特异性结合;复杂样品的最佳选择
目标细胞群 B细胞
储存条件 2℃ - 8℃ 保存

验证数据

Efficient 去除 of Human B Cells Using the SOLIDEX®-ISOEx 间接人CD19+ B细胞 去除 Kit (柱式)

产品货号 GM-Tg-hg-T56365-dep-kit
To evaluate the depletion efficiency of the SOLIDEX®-ISOEx 间接人CD19+ B细胞 去除 Kit (柱式), human PBMCs were incubated and labeled with Biotin-CD19 antibodies and anti-biotin nanobeads, followed by magnetic column separation. The unlabeled target cells passed through the separation column and were collected, while the magnetically labeled CD19+ B cells were retained within the column. Following the magnetic separation, both pre- and post-depletion cell samples were analyzed by flow cytometry. The flow cytometry plots demonstrated that the initial proportion of B cells in the pre-depletion PBMC sample was 10.1%, whereas the residual B cell proportion in the flow-through fraction after efficient depletion plummeted to 0.091%. The logarithmic depletion for this process reached 2.14. This indicates that the product is capable of highly efficient depletion of non-target B cells.

Figure 23. Efficient depletion of human B cells using the SOLIDEX®-ISOEx 间接人CD19+ B细胞 去除 Kit (柱式). In this experiment, CD19+ B cells were magnetically sorted and depleted from PBMCs. The results show a significant decrease in the proportion of CD19+ B cells in the sample, dropping from 10.1% pre-depletion to 0.091% after depletion.

ISOEx 细胞分离试剂盒 & 纳米磁珠 validation
Click to Zoom

需要更多产品数据或案例?

✉ 联系我们 / 获取报价
Product Image